ENGLISH 10
Injector table
Type of gas used Type of burner Injector
marking
Rated thermal
Rated
consumption
Reduced heat
capacity kW
Gas pressure (mbar)
min. rat. max.
PL
NATURAL GAS
(Methane)
G20
rapid
semi-rapid
semi-rapid
auxiliary
125A
104B
104B
78A
3,00
2,00
2,00
1,00
286 l/h
190 l/h
190 l/h
95 l/h
0,60
0,35
0,35
0,30
16 20 25
NATURAL GAS
G2.350
rapid
semi-rapid
semi-rapid
auxiliary
170D
136
136
104
3,00
2,00
2,00
1,00
397 l/h
264 l/h
264 l/h
132 l/h
0,60
0,35
0,35
0,30
10 13 16
NATURAL GAS
G27
rapid
semi-rapid
semi-rapid
auxiliary
142B
119A
119A
85D
3,00
2,00
2,00
1,00
348 l/h
229 l/h
229 l/h
116 l/h
0,60
0,35
0,35
0,30
16 20 23
LIQUEFIED
PETROLEUMGAS
(Propano)G31
rapid
semi-rapid
semi-rapid
auxiliary
79
66
66
47
3,00
2,00
2,00
1,00
218 g/h
143 g/h
143 g/h
73 g/h
0,70
0,45
0,45
0,35
25 37 45
HU*
NATURAL GAS
(Methane)
G20
rapid
semi-rapid
semi-rapid
auxiliary
119
100 B
100 B
74
3,00
2,00
2,00
1,00
286 l/h
190 l/h
190 l/h
95 l/h
0,70
0,40
0,40
0,35
20 25 33
NATURAL GAS
(Methane)
G25.1
rapid
semi-rapid
semi-rapid
auxiliary
135
108
108
81
3,00
2,00
2,00
1,00
332 l/h
221 l/h
221 l/h
111 l/h
0,60
0,35
0,35
0,30
18 25 33
LIQUEFIED
PETROLEUMGAS
(Butano) G30
(Propano)G31
rapid
semi-rapid
semi-rapid
auxiliary
85 A
69
69
50
3,00
2,00
2,00
1,00
218 g/h
145 g/h
145 g/h
73 g/h
0,60
0,35
0,35
0,30
20 28-30 35
Type of gas used 4 BURNERS
60 cm
Rated thermal
Total rated
consumption
Air required (m
3
) for
burning1m
3
of gas
PL
G20
20 mbar
1R-2SR(2kW)-
1 AUX
8,00 761 l/h 9,52
G2.350
13 mbar
1R-2SR(2kW)-
1 AUX
8,00 1057 l/h 6,85
G27
20 mbar
1R-2SR(2kW)-
1 AUX
8,00 922 l/h 7,90
37 mbar
1R-2SR(2kW)-
1 AUX
8,00 581 g/h 30,94
HU*
G20
25 mbar
1R-2SR(2kW)-
1 AUX
8,00 761 l/h 9,52
G25.1
25 mbar
1R-2SR(2kW)-
1 AUX
8,00 885 l/h 8,187
30 mbar
1R-2SR(2kW)-
1 AUX
8,00 581 g/h 30,95
* If the appliance is intended to be in use in Hungary, injectors already assembled (G20 - 20mbar) must
bereplacedaccordingtoHungarianmarketregluation,availableinInstructionforUser.
Injectorsforreplacementareavailableinthekit.PleaserefertoUserManualinformation.
Injectorreplacementmustbedonebyaqualiedtechnician.