ENGLISH 119
Gas adjustments
Use pressure regulators that are suitable
for the gas pressure values indicated in the
injectors table.
If the appliance is arranged for a type
of gas different from that available, it is
necessary to change the injectors, adjust
theminimumame,changetheoutlet
connector.
Carry out the following operations to
change the hob injectors: remove the grills;
remove the burners, the burner caps (see
Fig. 6); change the injector and replace it
with one suitable for the new type of gas
(see injectors table).
Fig. 6
Replace the gas calibration label with the
new label included in the injector bag.
Reteverythinginreverseorder,making
suretocorrectlyttheburnercaponthe
burner.
Minimum ame for hob taps
Toadjusttheminimumame,proceedas
follows:
Light the burner and turn the knob to •
minimum ; remove the tap knob. Insert
a small screwdriver next to the tap pin
(Fig. 7).
Fig. 7
Turn the adjustment screw anticlockwise to
increasetheame,orclockwisetodecrease
it. Adjustment is correct when the ame is
approx. 3 - 4 mm.
The adjustment screw must be completely
screwed down for butane/propane gas.
Makesuretheamedoesnotgooutwhen
switching suddenly from high to low ame
and vice versa.
Rettheknob.
Gas appliances
This appliance is not connected to a fume
exhaust device.
Therefore it must be installed and connected
in compliance with current and local
installation regulations.
Particular attention must be paid to the
applicable standards concerning room
ventilation.